Restoring somatosensory feedback is essential for achieving natural, embodied control of prosthetic limbs. Intracortical microstimulation (ICMS) of the somatosensory cortex can provide artificial touch by activating cortical neurons directly. Here, we systematically investigate how electrode contact size influences amplitude discrimination performance during ICMS.

Six rats were chronically implanted with custom multielectrode shanks in the somatosensory cortex. Over twelve weeks, behavioral just-noticeable differences (JNDs) were quantified across eight electrode diameters (5–50 µm) using an adaptive discrimination paradigm. Discrimination thresholds were significantly lower for 5 µm and 10 µm sites than for larger contacts because these electrodes operated at lower reference stimulation amplitudes within their established charge injection safety limits.

Weber fractions remained stable across electrode sizes, demonstrating proportional scaling of perceptual sensitivity with stimulus intensity. We used a biophysically realistic modeling framework to identify the underlying neural correlates of ICMS-induced amplitude discrimination. Both the magnitude of neural responses (changes in the number of activated neurons and the total population spike count) and the population mean spike count contributed to perceptual discrimination.

Together, these findings show that ultra-microelectrodes produce smaller absolute JNDs by enabling operation at lower currents, rather than by improving discrimination sensitivity at matched currents. Their preservation of Weber-like scaling within safe charge-injection limits may be advantageous for high-density sensory neuroprostheses. This material is based upon work supported by the National Institutes of Health under Grant NIH 1U01NS126052-01 “Engineering the neuronal response to electrical microstimulation” and the National Science Foundation Graduate Research Fellowship Program under Grant NGE-244108.

Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Institutes of Health or National Science Foundation. We would like to sincerely thank Elizabeth Olivo and Yupeng Wu for providing the detection threshold data and the voltage transient data, respectively, used to guide this study. Electron microscopy was performed using instrumentation in the Purdue Electron Microscopy Center (RRID:SCR_022687).

Weldon School of Biomedical Engineering, Martin C. Jischke Hall of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN, 47907-2032, USA Elizabeth T.

Extract — continue reading at the source.

Read full story